Outline
|
Layup: This equipment, after Tabbing, cuts the ribbon into specified length then layers the “+,-“ on top of the Jig Pallet.
Bussing: Bus Bar is cut then supplied to the String electrode and automatically soldered.
|
|
Specification
|
Capacity
|
Wafer 6” 6P*10Cell , 360 String/1Hr Tact Time = 60Sec
|
|
LayUP
|
Traverse [Stringing Cell Moving from Taber]
|
|
Transfer-1 [Loading to Alignment / Buffer Stage]
|
|
Transfer-2 [Loading to Edge Ribbon Cut Stage]
|
|
Buffer 4 Station
|
|
Stringing Alignment
|
|
Edge Ribbon Adjust Cutter
|
|
String to String Pitch : 2±0.5mm, 3±0.5mm
|
|
Bussing
|
Transfer-1 [Load to Jig Pallet]
|
|
Transfer-2 [Load to Glass EVA Sheet]
|
|
Bushing Jig Pallet
|
|
Pallet Return Equipment
|
|
Straight Ribbon Bushing Equipment
|
|
Angle Ribbon Bushing Equipment
|
|
Bus Bar Straight: (after cutting)_R/L ±0.2mm
|
|
Bus Bar 90˚ Disposition ±0.5˚
|
|
Soldering Cross area Over 80% (Peel test ]
|