Product Description
Remarkably Well-Designed and Incredibly Convenient
Wisdom-P is designed to facilitate a wide range of procedures through two detectors for clinics or hospitals.
Its compact and clever design delivers high-performance as well as cost-effective
operation through ease-of-use which fully meet the demands on quality and versatility with affordable price.
The overhead tube crane is basically manual, but it includes motorized movement for the z-axis to be synchronized with other radiographic components.
Configuration
Overhead Tube Crane
Wall Bucky Stand
4-Way or 6-Way Patient Table
| Ceiling-Mounted Tube Support |
| Display with color LCD screen on the tube housing |
| Workflow is enhanced through direct manipulation of examination parameters listed below |
| - SID (Source-image distance) measurement |
| - Display angle of tube rotation |
| - Display of the workplace: Bucky wall stand or table |
| - Display auto or manual mode |
| Tube Travel Range |
- Vertical travel motorized in auto mode
- Vertical travel range: 150cm(59 in.)
- Rotation range around the vertical axis: -150° to +180° manual Detent at 0°; ±90°
- Rotation range around the horizontal axis: ±150°manual Detent at 0°; ±90°
|
| Horizontal Travel Range |
Longitudinal: 332 cm (130.7 in.) with 4 m trolley
Transverse: 225 cm (88.6 in.) with 3 m trolley |
| Power Requirement |
UL: 120 VAC, 50/60 Hz, 500 VA
CE: 220 ~ 240 VAC, 50/60 Hz, 500 VA
|
| 6-Way Patient Table (Manual) |
| The table can be equipped with cassettes or a mobile flat detector for optimal coverage and high patient throughput |
| Tabletop Dimensions |
220 cm x 80 cm (86.6 in. x 31.7 in.) |
| Table Height |
54.5 cm to 84.5 cm; total lift 30 cm (tabletop) |
| Tabletop Travel Range |
Longitudinal: ±43 cm (±16.9 in.)
Transverse: ±12 cm (±4.7 in.) |
| Detector Travel Range |
44 cm (17.3 in.) |
| Max. Patient Weight |
250 kg (551 Ib) |
| Kick Switch |
For table height and float adjustments
(Wireless Foot Switch) |
Auto-tracking during table height adjustment
(Only with ceiling-mounted tube support) |
X-ray tube follows table height adjustment; SID
(source-image distance) is maintained |
| Power Requirement |
100 ~ 240 VAC, 50/60 Hz, 3A |
| Wall Bucky Stand (Manual) |
| The stand can be equipped with cassettes or a mobile flat detector for optimal coverage and high patient throughput |
| Manual Movement |
Vertical travel with electric magnet brake |
| Vertical Travel Range (central beam- floor) |
Max. : 188 cm (74 in.)
Min. : 40 cm (15.7 in.) |
| Power Requirement |
24 VDC, 1A |
-Specifications subject to change without notice.