Model
|
PWF900
|
PWF2500
|
|
Suit pipe sizes MM (INCH)
|
DN40~DN900 (1½”~36")
|
DN50~DN2500 (2"~100")
|
|
Pipe connection
|
1½” or 2” BSP or NPT male
|
2” BSP or NPT male
|
|
|
FLOW RANGE
|
|
Liters / Sec
|
0.25~6,300
|
0.4~49,000
|
|
US GPM
|
4~100,000
|
6~780,000
|
|
|
FLOW VELOCITY RANGE
|
|
Meter / Sec
|
0.3~10
|
|
Feet / Sec
|
1~33
|
|
|
METER PERFORMANCE AND ACCURACY
|
|
Linearity
|
typically ±1.5% with well established flow profile
|
|
|
TEMPERATURE RATINGS
|
|
Standard
|
-40ºC~+100ºC (-40ºF~+212ºF)
|
|
Maximum
|
up to 150ºC (300ºF max.)
|
|
|
PRESSURE RANGE
|
|
Maximum Pressure
|
80 bar (1160 PSI)
|
|
|
STANDARD MATERIALS
|
|
Body
|
316 Stainless Steel
|
|
Rotor
|
PVDF with 316 Stainless Steel Rotor shaft
|
|
O-Ring
|
Viton
|
|
|
ENVIRONMENTAL CLASSIFICATION
|
|
Protection Class
|
IP68 (NEMA6)
|
|
|
PULSE OUTPUTS
|
|
Reed switch
|
30Vdc x 200mA max. Nom. 0~80 Hz
Note: Maximum thermal shock is 10ºC (550ºF) / min.
|
|
Hall effect
|
3 Wire NPN, 5~24Vdc, 20mA max. Nom. 0~240 Hz
|
|
Voltage Pulse
|
Self generated voltage Nom. 0~240 Hz
|
|
Non magnetic sensor
|
3 Wire NPN, 5~24Vdc, 20mA max. Nom. 0~240 Hz
|
|
|
INTEGRAL OPTIONS
|
|
Outputs
|
4-20 mA, Scaled Pulse, Quadrature Pulse, Flow Alarms, 2-stage batch control
|
|
Hazardous Classification
|
Integral instruments can be supplied I.S. (Intrinsically Safe)
|