product Image
[Mass Flow Switch] 열식질량유량계 - DeltaM
Model Name
FS4200
Series
Inline thermal mass flow meter
Manufacturer information
provider logo
M&C ENGINEERING

Flowmeter and various instruments

Problem with product info?
Update request
Manufacturer
M&C ENGINEERING
Product Type
Machine
Brand
-
SKU
139842
Product Name
[Mass Flow Switch] 열식질량유량계 - DeltaM
Model Name
FS4200
Size
-
Weight
-
Product Details

Single Channel Mass Flow - Model FS 4200
microtuf ®

 

Main Feature

  • Mass Flow Switch for the detection of the mass flow rate of liquids and gases.
  • Wide operating temperature range -100°F to +850°F (-70°C to +458°C).
  • Wide flow range of .01 to 5 feet per second (fps) in oil, 2.5 fps in water and .1 to 500 fps in gases.
  • Two year workmanship warranty.
  • Free of all moving parts that can stick, coat or fail.
  • Fast response time of .5 to 10 seconds depending on the media.
  • Self heating sensor design improves repeatability. No separate heater to fail or slow response time.
  • CE, CENELEC and CSA Approved.

 

 

Specification

Sensor

  • Type: Thermal Differential, Dual RTD Sensors
  • Process Connection: Standard  0.75 inch MNPT
    Optionally  0.5 inch and larger MNPT and various other
    process connections such as sanitary and flanges
  • Insertion Length: Standard  2.0 inch Optionally  0.5 inch or greater
  • Operating Temperature Range :
    Standard  -100F to 390F (-70C to +200°C)
    Medium Temperature to +572F  (+30°C)
    High Temperature to +850F  (+458°C)
  • Materials of Construction: Standard  316L Series Stainless Steel
    Optionally  Hastelloy, Monel, Inconel and other exotic materials
  • Operating Pressure Range: Standard  to 3000 psia (207 bar)

 

Electronics

  • Power: Standard  110VAC Optionally 220VAC, or 24VDC at 3 watts (No heater power required)
  • Operating Temperature Range:
    Standard  -40F to +140F  (-40C to +60C)
    Optionally  remote electronics for use in medium and high-temperature environments
  • Outputs: DPDT Relay contacts rated at 5 amp, 250 VAC with fail safe capability
  • Self-Test:  Integral and Automatic during power up
  • Enclosure: Explosion proof; NEMA 3, 4X, 7, and 9; CSA, FM, UL, CENELEC, and EECS approved

 

Instrument

  • Operating Range: Adjustable Flow Rate (feet per second - fps), typical: 0.01 to 5.0 fps oil, 2.5 fps water and 0.1 to 500 fps gases
  • Response Time: Sensor response time 0.5 to 10 seconds media dependent
  • Stability: Drift < .5% from calibrated setpoint over a range of  +/-50 F.  Temperature compensated throughout entire range
  • Repeatability: ¡¾1% of setpoint
  • Approvals:  CE, CSA,CENELEC Class 1 Div. 1 Groups B, C, & D

 

 

Model Selection Guide

M&C ENGINEERING
M&C ENGINEERING
Flowmeter and various instruments
Inquiry