- Once the bowl fills capacity with waste solids,The Automatic cleaning Cycle is activated to remove the Solids. This Cycle is controlled by an adjustable Process Timer.
- When the cleaning cycle is activated, The Separator shuts off The Feed and brakes to a complete Stop.
- After the Free Liquid drains, The Sludge chute cover is pneumatically opened.
- A second Pneumatic Cylinder engages the plow mechanism’s clutch socket into the plow shaft. The sprocket then turns, counter rotating plow blades altermately, clockwise and counter clockwise.
- The Plowing Action discharges the compacted solids from the tapered Section of the Separator Bowl. The sludge drops through a chute into a waste receptacle below The Machine.
- Upon completion of the cleaning cycle, the sludge chute cover closes,the pneumatic cylinder retracts,The Process Timer resets,and the machine resumes its process cycle. A normal cleaning cycle takes less than 5 minutes.
|