Liquid filled thermometer is used for measuring temperature of corrosive and non-corrosive fluid in all industries. It operates in aggressive and non-aggressive environment. Linear dials and temperature compensate line assure an accurate temperature indication at varying ambient conditions.
Nominal diameter
100 and 150 mm
Accuracy
±2.0 % of full scale
Measuring system (SAMA class ⅢB)
Organic gas : 0 ~ 200 °C Inert gas : -200 ~ 700 °C
Working range
Maximum scale value
Standard features
Location of stem and mounting
Bottom connection, surface, case mounting lower back connection, flush, case center mounting bracket
Case
304SS
Cover
304SS
Capillary
Capillary : 1.6/0.2 mm, 316SS Armored tube : 7.5/5.5 mm, 304SS