분광기, 분광 시스템, 그레이팅, 회절격자, 카메라 시스템, OEM 제조업체
Mini Raman Spectrometer
Raman CCD spectrometer with high sensitivity and dynamic range for OEM Raman hand-held applications.
ㆍ High throughput (f/3.1)
ㆍ Three Raman laser ranges: 532nm and 785nm
ㆍ Ultra-miniaturization with CCD USB 2.0 electronics
ㆍ 7000:1 dynamic range
ㆍ SMA or permanent fiber-optic connection
ㆍ VIS- or NIR-optimized back-illuminated CCD
ㆍ CCT optical layout (Crossed-Czerny-Turner)
  Available for US OEM customers only
| 
 Feature  | 
 Benefits for Spectroscopy  | 
| 
 Raman range with 785 nm  | 
 210 to 2700 cm–1 coverage  | 
| 
 High dynamic range  | 
 7000:1 with low readout-noise of 35 e–  | 
| 
 Back-illuminated linear CCD  | 
 QE=77% at 600nm;55% at 850nm with VIS-optimized (NIR-optimized option: yields 75% QE at 850 nm)  | 
| 
 USB 2.0 high and full-speed  | 
 Standard connection interfaces to PCs with 100% data integrity  | 
| 
 Windows®acquisition software and LabVIEW™ VIs and DLLs available  | 
 Software to integrate MINI-CCT+ as an OEM component  | 
| 
 No moving parts or shutter  | 
 Excellent reliability for OEM integration  | 
 
Available for US OEM customers only
| 
 Spectral coverage  | 
 With 532 nm laser:210 to 3500 cm–1  | 
| 
 Numerical aperture  | 
 F/3.1  | 
| 
 Stray light rejection  | 
 0.1% (0.2%)  | 
| 
 CCD Detector & Typical Q.E.  | 
 Back-illuminated CCD with low etaloning in NIR  | 
| 
 Detector height  | 
 300μm CCD height standard (1000μm optional)  | 
| 
 Thermoelectric stabilization  | 
 None. Dark current and CCD-pattern noise must be subtracted. User must shutter in optical path. QE shifts slightly with temperature.  | 
| 
 Spectral resolution  | 
 785nm configuration;25μm slit; 2048 pixels; 8–12cm–1 resolution; 0.19nm/pixel (configuration with 300μm tall CCD)  | 
| 
 Improved CCD full well  | 
 >250Ke- (sensitivity mode) < 0.4% (sensitivity mode)  | 
| 
 Typical dynamic range  | 
 7000:1 in sensitivity mode  | 
| 
 Readout speed  | 
 8.6ms (500kHz mode); 116 spectra/s with 0 exposure time (Multi-Acq mode)  | 
| 
 Typical Dark current  | 
 1 count/ms at 20°C (room temp.); typical offset = 1000 counts  | 
| 
 Typical readout noise  | 
 35 e- (Max= 45e-) in sensitivity mode (4 e–/count)  | 
| 
 A/D converter  | 
 16 bit, 500 kHz (pixel rate); optional 2 MHz VIS-CCD  | 
| 
 Typical dynamic range  | 
 7,000:1 in sensitivity mode  | 
| 
 Weight  | 
 1.8 lb (0.82 kg)  | 
| 
 Gain selection  | 
 4 e-/count and 8 e-/count  | 
| 
 Dimensions (H× W×D)  | 
 4” × 2.71” × 1.49” (101.6 mm × 68.8 mm × 37.8 mm)  | 
| 
 * Specifications, Form Factor and Spectrometer Covers are subject to change without notice.  | 
|
Acquisition software included (LabVIEW™ 2011 only)
ㆍ VIs and top-level code are provided for customer customizations
ㆍ Access to data with raw CCD linearity and corrected linearity done at factory for each CCD chip
ㆍ CCD settings and dark-subtract
ㆍ On-board or software averaging
ㆍ Scale selection between pixel, wavelength, and wavenumber
ㆍ On-board spectral calibration
ㆍ Linearity correction on/off
ㆍ save function to Excel® or text file
No LabVIEW™ license is needed to run our acquisition software. LabVIEW™ license ver. 2011 required to edit our code. No code customization supported in price.