- For motor with straight shaft, please write S in place of PF in Motor Type.
- Motor Type in green screen represents the motors with TP(Thermal Protect) according to UL or CE regulation.
- It cannot be used continuously because the temperature rises rapidly when the load is greater than the rated load or the surrounding temperature exceeds 40℃
- when changing the direction of rotation, make sure to turn off the power and reconnect it at stopped state.
■ MOTOR(STRAIGHT SHAFT) I(R)HT8S25 WT 1.6kg
■ GEARED MOTOR I(R)HT8PF25 + 8H□ FM(8H□ FB)WT 1.6+0.5/0.6kg
■ BOLT SIZE
No
L(mm)
GEAR RATIO
BOLT SIZE
01
32
1/3 ~ 1/20
M5×60
02
42
1/25 ~ 1/200
M5×70
■ KEY SPEC
■ WIRING DIAGRAM
- The direction of rotation is seen from the end of motor shaft.
- Change the rotation direction of the motor only after the motor stops completely.