SMF Series, ACEMAG-SMF Series, SMF-H Series, SMF-R Series, SMF-S Series
Size
-
Weight
-
Product Details
TYPE & MODEL
MAGNETIC FLOW METER
PRINCIPLE
Electromagnetic Flowmeter AceMag operates on Faraday's law of induction and Fleming's rule that state that the signal voltage(UE) is generated through the X-axis which is perpendicular to the conductor moving direction(Z-axis) and the magnetic field(Y-axis) around the moving conductor(fluid) when a conductor moves through the perpendicular direction to the line of magnetic force which is the magnetic intensity(B) in the space, and this signal voltage(UE) is directly proportional to the magnetic density(B) and the average fluid velocity(V).
AceMag measures and indicates the flow rates based on the above explained theory.
INDUSTRY
Industrial Plant, Petrochemistry, Environmental Water Treatment, Nuclear/Power Generation Plant