New concept of drug infusion pump that does not need distinction between Infusion & Syringe
Anyfusion H-100 (Horizon Type)
Infusion Pump and syringe pump are
Integrated into one device : Cylinder Pump
1. Truly Precise
- Real-time precise injection for maximum 72 hrs within ± deviation in all range
2. Truly Safe
- Automatic safety lock / Alarm Function
- Free flow, Startup delay / InadvertentใAccidental Bolus / Shiphoning Phenomenon prevention
- Minimize the risk of infection and contamination
3. Truly Easy
- Directly connect to the container
· No need to diverge
· dispense drug
- No need to distinguish the use of infusion pump or Syringe pump depending on uses and functions
- Unrestricted use in place or height (Operating room, Ward, etc.)
- Auto priming
- Capable of PCA (Patient Controlled Analgesia) function
- Minimize human workload in drug injection
- Smart stacking structure maximizes space utilization
- minimization of discarded drug & medical disposables (syringe, container, etc.)

Specification
| Product name |
Cylinder pump |
| Model name |
Anyfusion H-100 |
| Flow rate |
0.1 ~ 999.9 ml/hr |
| Flow rate accuracy |
±2% |
| VTBI selector, ml |
0.1 ~ 9999ml |
| Total Volume |
0.01 ~ 9999ml |
| KVO rate |
0.1 ~ 5 ml/hr |
| IV set |
Compatible with any brand of IV sets
(Compatible with installed micro filter 0.2~5.0um)
|
| Purge rate, ml/hr |
999.9 ml/hr |
| Bolus rate, ml/hr |
999.9 ml/hr(default), 50 ~ 999.9 ml/hr |
| Bolus volume |
0.1 ~ 99.9ml |
| Occlusion pressure |
150 ~ 750 mmHg |
| Display |
4.3" TFT-LCD (Resolution : 480 x 272) |
| Alarm |
|
- Infusion completed alarm
- Start reminder alarm
- Input time expired alarm
- Low battery alarm
- No battery alarm
- Depleted battery alarm
|
- Upstream occlusion alarm
- Downstream occlusion alarm
- Air-in-line alarm
- Door open alarm
- System malfucion alarm
- Cylinder detached alarm
|
|
| Power |
AC100 ~ 240V, 50/60Hz / Fuse : 250V, 1.6A |
| Batter type |
Rechargeable Li-ion |
| Battery life |
Approx, 8hrs at 100ml/h |
| Recharge time |
Approx. 5hrs |
| Power consumption |
Max. 75VA |
| Protection type |
- Protection from electric shock : Class 1
- Protection capacity for electric shock : Type CF
- Protection from liquid infiltration : IPX2
|
| Dimension |
22(W) x 145(D) x 96(H)mm |
| Weight |
Approx 1.9kg |
| Operating condition |
- Temperature : 10~40โ
- Humidity : 30~75%
- Atmospheric pressure : 700 ~ 1,060hpa
|
| Storage condition |
- Temperature : -20~60โ
- Humidity : 10~95%
- Atomosheric pressure : 650 ~ 1,060 hpa
|
| Accessories |
Syring holder, Pole clamp, AC power cord, Operator manual |