Target
Subject |
Smoke Opacity(%),
Smoke Density(m-¹)
Option : RPM, Temperature(℃) |
| Principle |
Light extinction method
(Partial-flow sampling type) |
| LED Type |
Green LED(565nm) |
| Detector |
Photo Diode |
| Range |
0.0~100.0% (0.00~21.42m-¹) |
| Accuracy |
Less than 1% |
| Preheat Time |
3~6 minutes |
| Display Time |
4 times/sec |
| Voltage Use |
220V / 110V AC 50/60Hz |
| Temperature |
-10~40℃ |
| Dimension |
450(W)×200(D)×245(425)(H)mm |
| Weight |
About 7kg |
| Option |
RPM/Oil Temp. Meter,
Handheld Terminal,
Built-in Printer,
Standard Filter,
PC Program |