Ecomonic:
① Micro smoke tube type structure that best fitness in small space installation.
② Realize high effectivenedd by optimum internal pressure in flue and installation of air pre-heater.
③ Reduce the fuel cost by reserve subordinate time (within 15 minutes)
④ It is horizontal type combusting structure with long-range of life-time durability
· Convenience:
① Automatic controlling system that all functions are achieved perfectly by single-touch
② Great convenience to manage and operate by the built in type additional equipment which related to automation.
③ High safety by the double or triple safety control system
④ Easy to manage and repair by the manual control system
· Place to use:
Fiber / Sewing factory / Chemical factory / Heating and hot-water supply / Sauna / Dye works / Hotel / Hospital / Drying rack / Laboratory / Bean curd factory / Brewery / Food factory / Drying rack / Brickyard / Deposit factory etc.

|
Division / Type
|
SMB-100
|
SMB-150
|
SMB-200
|
SMB-250
|
SMB-300
|
SMB-350
|
SMB-400
|
SMB-500
|
|
Proper Form of Evaporation
|
kg/h
|
1,000
|
1,500
|
2,000
|
2,500
|
3,000
|
4,000
|
5,000
|
6,000
|
|
Max. Working Pressure
|
kg/㎠
|
10{1.0MPa}
|
|
Efficiency
|
%
|
More than 90%
|
|
Electric Transmission Area
|
㎡
|
13
|
21.6
|
24
|
32.3
|
42
|
49.7
|
55
|
66
|
|
Weight
|
Ton
|
2.2
|
2.5
|
2.8
|
3.2
|
4.0
|
4.5
|
5.2
|
6.3
|
|
Titration
|
ℓ
|
1,300
|
1,383
|
1,687
|
1,927
|
2,775
|
3,013
|
5,303
|
6,890
|
|
Fuel Consumption
|
Light Oil
|
kg/h
|
67.5
|
101.3
|
135.1
|
168.9
|
202.6
|
236.4
|
270.2
|
337.7
|
|
LNG
|
N㎥/h
|
70.3
|
105.4
|
140.6
|
175.7
|
210.8
|
246
|
281.1
|
351.4
|
|
LPG
|
N㎥/h
|
31.1
|
46.6
|
62.2
|
77.7
|
93.3
|
108.8
|
124.4
|
155.4
|
|
Heavy Oil
|
kg/h
|
68.2
|
102.3
|
136.4
|
170.5
|
204.6
|
238.7
|
272.8
|
341.1
|
|
Capacitance of Electric
|
kW
|
4.8(6.35)
|
6.35(8.1)
|
8.45(10.45)
|
10.45(10.45)
|
11.25(14.75)
|
16.2
|
16.2(20.2)
|
20.2
|
|
Joint Valve
|
Main Steam Valve
|
A
|
50
|
65
|
80
|
80
|
80
|
100
|
100
|
125
|
|
Progression Valve
|
25
|
25
|
40
|
40
|
40
|
40
|
40
|
40
|
|
Drainage Valve
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
|
Safety Valve
|
25
|
32
|
40
|
40
|
40
|
50
|
25,40
|
40×2
|
|
Feed Oil Valve
|
20
|
20
|
25
|
25
|
25
|
25
|
25
|
25
|
|
Fuel Gas
|
25
|
40
|
40
|
40
|
50
|
50
|
50
|
50
|
|
Chimney
|
ømm
|
300
|
350
|
400
|
500
|
550
|
580
|
600
|
650
|
|
Minimum Dimension
|
Width
|
mm
|
1,300
|
1,340
|
1,450
|
1,450
|
1,710
|
1,800
|
2,140
|
2,240
|
|
Length
|
2,950
|
3,070
|
3,203
|
3,570
|
3,620
|
3,620
|
4,100
|
4,890
|
|
Height
|
2,040
|
2,130
|
2,377
|
2,500
|
2,587
|
2,800
|
2,920
|
3,210
|
|
Maximum Dimension
|
Width
|
mm
|
1,980
|
2,074
|
2,200
|
2,248
|
2,640
|
2,800
|
2,980
|
3,328
|
|
Length
|
3,000
|
3,164
|
3,420
|
3,420
|
3,840
|
3,840
|
4,320
|
5,240
|
|
Height
|
2,290
|
2,400
|
2,500
|
2,900
|
3,020
|
3,320
|
3,570
|
3,780
|
※ Low calorific power of fuel
① LNG:41.45 MJ/N㎥{9,900kcal/N㎥}, ② LPG{Propane}:93.7 MJ/N㎥{22,380kcal/N㎥},
③ Light Oil:43.12 MJ/kg{10,300kcal/kg}, ④ Heavy Oil:42.7 MJ/kg{10,200kcal/kg}
※ The specification list are subject to change without prior notice to improve the performance and technology development.