Electric Heat Tracing (EHT)
De-icing system to Heli-deck is very important because if the pancake area and Heli-deck access are frozen, fatal accidents can occur during the helicopter taking off and landing.
E-TEC supplies the total heating solution for Heli-deck including pancake, walkway, stair, handrail, gutter and etc.
Specification
| Application | Heli-Deck Heating | |
|---|---|---|
| Type of Cables | Self-Regulating Heating Cable | |
| Supply Voltage | 208V ~ 277V (Standard : 230Vac) | |
| Rated output based on temperature of the surroundings(w/m) | 10℃ | 64 |
| -10℃ | - | |
| -20℃ | - | |
| -30℃ | - | |
| -40℃ | - | |