Features
Dust collector optimized for spaces with limited height
Filter Type
Cartridge Filter
Application
PCB processing work, metal processing work, casting cutting wok, mixing work, drilling work, cutting work, tailoring work, crushing, stone work
Specifications
Product Specifications

| TYPE |
Air volume(CMM) |
static pressure(mmAq) |
output(Kw) |
size |
weight(kg) |
| A width |
B length |
C height |
D total width |
E total length |
F total height |
G inlet(Ø) |
H outlet(Ø) |
| APH-200 |
30 |
230 |
1.5 |
1250 |
570 |
1135 |
1323 |
592 |
1350 |
200 |
250 |
45 |
| APH-300 |
40 |
230 |
2.2 |
1250 |
750 |
1135 |
1323 |
772 |
1350 |
250 |
300 |
65 |
| APH-500 |
65 |
230 |
3.7 |
1535 |
750 |
1100 |
1588 |
772 |
1315 |
250 |
300 |
83 |
Power and Filter Specifications
| TYPE |
Power |
filter |
| 60Hz(Premium),50Hz |
size |
quantity |
type |
| APH-200 |
220V 1P, 220V / 380V 3P 60Hz 440V(Option), 50Hz(Option) |
220V / 380V 3P 60Hz 440V(Option), 50Hz(Option) |
145X500L |
6 |
General(PET) water repellent coating flame retardant aluminum antistatic NOMEX PTFE(membrane) |
| APH-300 |
|
9 |
| APH-500 |
12 |
- Filter size : 145Ø, 165Ø (Option)
※ This specification may change without notice for performance improvement.
Filter
APH SERIES Filter Information
· Equipped with cartridge filter, it has wide filtration area and it is easy to replace by integrating with cell plate.
· The material is PET, membrane, Nomex, etc., and water-repellent antistatic (aluminum) treatment is applied according to the purpose.
|
Water Repellence
Prevents water invasion but lets air permeation
|
|
Flame retardance
Fire does not spread well
|
|
Antistatic(aluminum)
Superb antistatic
|
|
Membrane
Filtration efficiency of 0.3 fine dust is 99.9%, no fine dust emission, excellent dust removal performance extended filter life, response to environmental regulation
|
|
Membrance Filter

|
Characteristics of PTFE
· Heat and cold resistance: 150 degrees of usage temperature
· Chemical resistance: Inert to acid, alkali, etc.
· Electrical features: high insulation, high frequency
· Non-adhesive, combustion resistant
|
Efficient Filter Cleaning

Filter Cleaning System
① Filter cleaning by assigned differential pressure value
② Adjusting settings according to site situation
③ Automated cleaning by assigned cycle even after dust collector operation stops
TURBO BLOWER Information

In-house turbo fan production for the most efficient performance management system
|

High air Volume
|

High Wind Pressure
|

Low Vibration
|

low noise
|
Controller
The digital controller that puts your convenience as its number one priority

• Applied color LCD and soft touch switch
• Interface: Adopted standard mode to enable linked operation with external contacts
• Error Report: Displaying error alarm and alarm history when error occurs
• Digital differential pressure, digital current, operation integration, error status indicator function
• Dedicated Inverter Controller: Manual/Auto control of inverter