EXPlasma Z7

Model

Series

EXPlasma Z7


Transaction Process

Please contact the manufacturer/supplier.

Payment

Contact the manufacturer/supplier.

Delivery

Contact the manufacturer/supplier.

Shipment

Contact the manufacturer/supplier.

Origin

Contact the manufacturer/supplier.


Description

LOW TEMPERATURE PLASMA STERILIZER

EXPLASMA Z7


Low temperature sterilization below 60degrees minimizes damage to medical device

Maximize turnover rate of medical device

Economical cost similar to Autoclave

Vacuum system that does not require oil change

Provided IoT-based online sterilization report


CONDENSATION PHENOMENON

Low temperature plasma sterilizers are sensitive to moisture and temperature differences.

If there is moisture or a temperature difference, the hydrogen peroxide used as a sterilant may be on the medical device.

Preheating and moisture removal are very important.

EXPlasma is a sterilization solution that can minimize these problems.








AMR

AUTO MOISTURE REMOVAL

EXPlasma has automatic moisture removal function. So it can be used conveniently and safely even if it has a little moisture or slight temperature difference.












P-ART

POUCH ARTIFICIAL RESPIRATION TECHNOLOGY

P-ART technology is a unique technology of CUBE Instrument.

This can cause the sterilant to penetrate repeatedly into the medical device, such as artificial respiration, and shorten the sterilization time. And it is very effective for temperature transfer and moisture removal.


1st Generation Technology : SAE-I (Sterilization Acceleration Engine) - Chamber "Space Variable Technology" - Technology that optimizes sterilant and heat transfer by changing the pressure inside the chamber. (Patent application, Aug. 2016, registration, 2017. 04 (KR))




2nd Generation Technology : SAE-II - Optimized sterilization acceleration engine efficiency. - After the completion of sterilization, the remaining sterilant is minimized to improve the stability and convenience of the medical device. (Patent pending)

ModeFlashMin. 10 Minute
STANDARDMin. 20 Minute
TemperatureBelow 60 degrees
Dimensionwidth39 cm
Length44 cm
Height30 cm
Chamber volume7 liter
SterilantH2O2 50 wt%
Operation noisebelow 60 dB
Electrical RequirementAC 220 V / 60 Hz
Power consumption1,200 W
Total weight30 kg
Operationg temperature18 - 35 degrees
Operationg humidity10 - 80


Download

catalog-CUBE INSTRUMENT-EXPlasma Z7

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.