Single Channel Point Level Flow - Model LS 3200
microtuf ®
Main Feature
- Thermal point level switch for the detection of level in all vessels.
- Wide operating temperature range -100°F to +850°F (-70°C to +458°C).
- Switch on level change of .03 inch without concern for changing temperature, density, dielectric constant or chemical composition
- Two year workmanship warranty.
- Free of all moving parts that can stick, coat or fail.
- Fast response time of .1 to 1 second on wetting, media dependent.
- Self heating sensor design improves repeatability. No separate heater to fail or slow response time.
- CE, CENELEC and CSA Approved.
Specification
Sensor
- Type: Thermal Differential, Dual RTD Sensors
- Process Connection: Standard 0.75 inch MNPT
Optionally 0.5 inch and larger MNPT and various other
process connections such as sanitary and flanges
- Insertion Length: Standard 2.0 inch Optionally 0.5 inch or greater
- Operating Temperature Range :
Standard -100F to 390F (-70C to +200°C)
Medium Temperature to +572F (+300°C)
High Temperature to +850F (+458°C)
- Materials of Construction: Standard 316L Series Stainless Steel
Optionally Hastelloy, Monel, Inconel and other exotic materials
- Operating Pressure Range: Standard to 3000 psia (207 bar)
Electronics
- Power: Standard 110VAC Optionally 220VAC, or 24VDC at 3 watts (No heater power required)
- Operating Temperature Range: Standard -40F to +140F (-40C to +60C)
Optionally remote electronics for use in medium and high temperature environments
- Outputs: DPDT Relay contacts rated at 5 amp, 250 VAC with fail safe capability
- Self-Test: Integral and Automatic during power up
- Enclosure: Explosion proof; NEMA 3, 4X, 7, and 9; CSA, FM, UL, CENELEC, and EECS approved
Instrument
- Operating Range: Switch on level change of .03 inch. Available with insertion lengths from 0.5 inch to 30 feet.
- Response Time: Sensor response time 0.1 to 1 second media dependent
- Stability: Drift < .5% from calibrated setpoint over a range of ±50° F. Temperature compensated throughout entire range.
- Repeatability: +/-1% of setpoint
- Approvals: CE, CSA,CENELEC Class 1 Div. 1 Groups B, C, & D
Model Selection Guide