Model |
GER150 |
GER200 |
GER250 |
GER400 |
Size, W x H x D(mm) |
81×70×39 |
81×70×39 |
92×87×45 |
100×91×58 |
Contact |
Short-time Current |
150A (continuously, 50mm2) |
200A (contrnuously 50mm²) |
250A (continuously,100mm2) |
400A(continuously,150mm2) |
(Over Current) |
225A (15min., 50mm2) |
300A (2min 50mm²) |
350A (15min., 100mm2) |
600A (7min., 150mm2) |
|
320A (2min., 50mm2) |
400A (500sec 50mm²) |
500A (2min., 100mm2) |
800A (2min., 150mm2) |
Max. Cut-off Current |
1,500A at 450VDC (1cycle) |
1,500A at 450VDC (1cycle) |
2,500A at 400VDC (1cycle) |
1,500A at 450VDC (1cycle) |
Reverse Direction Cut-off |
-150A 200VDC (500 cycles at 20 CPM) |
-150A 200VDC (500 cycles at 20 CPM) |
-250A 200VDC (1,000 cycles at 6 CPM) |
-400A 200VDC (1,000 cycles at 1 CPM) |
Switch-off Life |
300A 450VDC (100 cycles at 1 CPM) |
300A 450VDC (100 cycles at 1 CPM)
|
400A 450VDC (100 cycles at 1 CPM) |
800A 450VDC (200 cycles at 1 CPM) |
Coil |
Pick-up Voltage (at 20℃) |
Max. 9VDC |
Max. 8VDC |
Max. 9VDC, 18VDC |
Max. 9VDC, 16VDC |
Drop-out Voltage (at 20℃) |
Min. 1.2VDC |
Min. 1.2VDC |
Min. 1.2VDC, 2.4VDC |
Min. 1.2VDC, 2.4VDC |
Max Power consumption |
6.5W (at 12VDC) |
6.5W (at 12VDC) |
4W (*inrush current: 2.9/ 1.25A for 12/24V) |
4.5W (*inrush current: 4.2/ 2.1A for 12/24V) |
Expected life |
Mechanical |
Min. 200,000ops (at 60CPM) |
Min. 200,000ops(at 60CPM) |
Min. 200,000ops (at 60CPM) |
Min. 200,000ops (at 60CPM) |
Electrical(Resistive Load) |
150A, 450VDC, 1,000ops (at 20CPM) |
200A 450V 1,000ops (at 6cpm) |
250A, 450VDC, 1,000ops (at 6CPM) |
400A, 450VDC, 1,000ops (at 6CPM) |
15A, 450VDC, 50,000ops (at 20CPM) |
240A 50V 75,000ops (at 6cpm) |
100A, 450VDC, 10,000ops (at 6CPM) |
200A, 450VDC, 3,000ops (at 12CPM) |
N / A |
N / A |
N / A |
N / A |