▶ 3100R/3200R/3300R/3400R/3400L/3420R/3420L/3900R: Motorized Actuators



Here is a line-up of motor-operated actuators of basically ON/OFF control. 3100 series is featured by small-size, lightweight and high output. 3400 series and 3420 series use case, cover, mounting portion, etc. commonly with a full-electronic actuator.

3900 series can be used for an inexpensive and simple instrumentation, with a potentiate mounted for detection of control position, besides small size and lightweight. Explosion-proof approved models are also replete. 




Specification


3100R Rotary stem motion type

Principal uses

2-position control

Power

Drive motor

Synchronous motor

Power supply

Single phase 100/110/200/220V AC 50/60 Hz

Motor rating

10 minutes

Control mechanism

Input signal

Switching contact

Ancillary mechanism

Overload protection

With built-in thermal protector

Space heater

- Optional

5W

Conditions for installation

Ambient temperature

-10 to 50°

Ambient temperature

- With space heater

-20 to 40°

Mounting position

Should not be mounted in an inverted position from the maintenance face.

Body portion

External sheath type

Protection class IP65 or equivalent

Wiring port

G1/2 (1 place)

Wiring port

- Optional

Various adaptors can be mounted

Installation seat

Conforms to ISO





3200R Rotary stem motion type

Principal uses

2-position control

Power

Drive motor

AC reversible motor

Power supply

Single phase 100V AC 50/60Hz

Power supply

- Optional

Single phase 110/200/220V AC 50/60Hz

Motor rating

30 minutes

Control mechanism

Input signal

Switching contact

Opening signal transmission

- Optional

Potentiometer (5kΩ/135Ω)

Ancillary mechanism

Control position detection

- Optional

Auxiliary limit switch (voltfree), maximum points of detection 2 places

Overload protection

With built-in thermal protector

Space heater

- Optional

* Please contact us for details, as this matter depends on the power supply voltage.

Conditions for installation

Ambient temperature

-10 to 50°

Ambient temperature

- With space heater

-20 to 40°

Mounting position

Should not be mounted in an inverted position from the maintenance face.

Body portion

External sheath type

Protection class IP65 or equivalent

Wiring port

G1/2 (1 place)

Wiring port

- Optional

Various adaptors can be mounted

Installation seat

Conforms to ISO





3300R Rotary stem motion type

Principal uses

2-position control / Endless control / Multi-revolution control

Power

Drive motor

AC reversible motor

Power supply

Single phase 100V AC 50/60Hz

Motor rating

30 minutes

Control mechanism

Input signal

Switching contact

Input signal

- With control pack

4 to 20mA DC or 1 to 5V DC

Opening signal transmission

- Optional

Potentiometer (5KΩ/135Ω)

Ancillary mechanism

Control position

detection-Optional

Auxiliary limit switch (voltfree), maximum points of detection 2 places

Dismountable handle type,

wit clutch- Optional

Dismountable handle type, wit clutch

Overload protection

With built-in thermal protector

Space heater

- Optional

* Please contact us for details, as this matter depends on the power supply voltage.

Control

- Optional

Control pack (endless type cannot be mounted)

Conditions for installation

Ambient temperature

-10 to 50°

Ambient temperature

- With space heater

-20 to 40°

Mounting position

Should not be mounted in an inverted position from the maintenance face.

Body portion

External sheath type

Protection class IP55 or equivalent

Wiring port

G1/2 (1 place)

Wiring port

- Optional

Various adaptors can be mounted,

Terminal box

Installation seat

Conforms to ISO





3400R Rotary stem motion type/3400L Linear stem motion type

Principal uses

2-position control

Power

Drive motor

AC reversible motor

Power supply

Single phase 100V AC 50/60Hz

Power supply

- Optional

Single phase 110/200/220V AC 50/60Hz

Motor rating

30 minutes

Control mechanism

Input signal

Switching contact

Opening signal transmission

- Optional

Potentiometer (5KΩ/135Ω)

Ancillary mechanism

Control position detection

- Optional

Auxiliary limit switch (voltfree), maximum points of detection 2 places

Dismountable handle type

Dismountable handle type

Overload protection

With built-in thermal protector

Overload protection

- Optional (3400R)

Torque switch on closed side (CW direction only)

Space heater

- Optional

* Please contact us for details, as this matter depends on the power supply voltage.

Conditions for installation

Ambient temperature

-10 to 50°

Ambient temperature

- With space heater

-20 to 40°

Mounting position

Should not be mounted in an inverted position from the maintenance face.

Body portion

External sheath type

Protection class IP55 or equivalent

Wiring port

G3/4 (3400R) G1/2 (3400L) 2 places

Wiring port

- Optional

Various adaptors can be mounted

Terminal box (3400L)

Installation seat

Conforms to ISO





3420R Rotary stem motion type/3420L Linear stem motion type

Principal uses

2-position control

Power

Drive motor

AC reversible motor

Power supply

Single phase 100/110V AC 50/60Hz (+/- 5%)

Power supply

- Optional

Single phase 200/220V AC 50/60Hz (+/- 5%)

Motor rating

30 minutes

Control mechanism

Input signal

Switching contact

Opening signal transmission

- Optional

Potentiometer (5KΩ/135Ω)

Ancillary mechanism

Control position detection

- Optional

Auxiliary limit switch (voltfree), maximum points of detection 2 places

Dismountable handle type

With handle insertion hole

Overload protection

With built-in thermal protector,

Torque switch (3420R is an option)

Space heater

- Optional

* Please contact us for details, as this matter depends on the power supply voltage.

Conditions for installation

Ambient temperature

-10 to 50°

Ambient temperature

- With space heater

-20 to 40°

Mounting position

Should not be mounted in an inverted position from the maintenance face.

Body portion

Wiring port

G1/2 (2 places)

Wiring port

- Optional

Various adaptors can be mounted

Terminal box

Installation seat

Conforms to ISO





3900R Rotary stem motion type

Principal uses

2-position control

Power

Drive motor

AC reversible motor

Power supply

Single phase 100/110V AC 50/60Hz (+/- 5%)

Power supply

- Optional

Single phase 200/220V AC 50/60Hz (+/- 5%)

Motor rating

30 minutes

Control mechanism

Input signal

Switching contact

Opening signal transmission

- Optional

Potentiometer (1KΩ/135Ω)

Ancillary mechanism

Control position detection

- Optional

Auxiliary limit switch (voltfree), maximum points of detection 2 places

Dismountable handle type

With handle insertion hole

Overload protection

With built-in thermal protector

Space heater

- Optional

* Please contact us for details, as this matter depends on the power supply voltage.

Conditions for installation

Ambient temperature

-10 to 50°

Ambient temperature

- With space heater

-20 to 40°

Mounting position

Should not be mounted in an inverted position from the maintenance face.

Body portion

External sheath type

Protection class IP65 or equivalent

Wiring port

G1/2 (2 places)

Wiring port

- Optional

Various adaptors can be mounted,

Terminal box

Installation seat

Conforms to ISO

문의하기