Operating principle Layer consist of individual small magnetic flag, which half color red and the other half white and can be turned each by each, and it is mounted to the front chamber. As liquid level rises, a magnet-equipped float withch the unit inverts the magnetic flags in the external indicator to “color-side-out.” The flags remain magnetically interlocked in a column until again inverted to “contrasting-side-out” by the float as liquid level falls. Liquid level is indicated by the junction of the “color” and “contrasting” portions of the column.
Description of model
Standard Model and specifications
Symbol
Mounting method
Connection size
Working condition
Specific grave
Accuracy
Material
Press
Temp
Chamber
Float
Flag
Flag Chamber
DMLG-S-□-□
Side-Side
JIS 5K 25A
5kg /㎠
200℃
Over 0.8
±10m/m
SUS304
SUS304
Polycarbonate
Aluminum
DMLG-T-□-□
Top
JIS 5K 100A 0r 125A
5kg /㎠
200℃
Over 0.8
±10m/m
SUS304
SUS304
Polycarbonate
Aluminum
Standard Model and specifications
Description
Module
Output
Contact rating
Contact form
Power source
Accuracy
Material
No.of point
Mesasuring range
Max.working temp
Enclosure
Housing
Transmitter
Level swich
Reed swich
Dry contact
125VAC, 0.5A
S.P.D.T (No,Nc,Com)
N/A
±5m/m
AC
N/A
Max.6
N/A
120℃
Weather proof
Level transmitter
Reed swich and resistors
4-20mA DC Two-wire
N/A
N/A
DC 24V
±1.5% of F.S
AC
SUS304
N/A
400 ~ 5000m/m
120℃
Weather proof
These switch & transmitter modules can be intrinsically safe by using the I.S barrier Please consult with our factory when other condition are required. s