■ GENERAL SPECIFICATION

- Speed Controller with Tacho Generator

- Plug-in type for standard 8pin socket

- Built-in speed setting (external speed setting applicable)

- Instantaneous stop by electric brake sircuit

- Various application

 

 

■ PERFORMANCE DATA

Controller Type HS□-11G HS□-11Y HS□-22G HS□-22Y
Rated Voltage 110V 220V
Voltage Range Rated Voltage ±10%
Line Frequency 50 / 60Hz
Motor Output 6 ~ 120W
TG Voltage 24V 12V 24V 12V
Speed Range 90~1400rpm / 90~1700rpm
Speed Variation 5% (Standard)
Speed Setting Built-in(External Setting Attatchable)
Brake Time Electric(By Breaking Current)
Parallel Operation Not Applicable
Slow Up · Down Not Applicable
Operation Temp. -10 ~ 40℃
Storage Temp. -20 ~ 60℃
Humidity Below 85%

■ OUTLINE DIMENSION

 

 

■ WIRING DIAGRAM

① ONE DIRECTION(일방향운전) + VARIABLE SPEED(가변)6W~120W

 

- To reverse the rotation from "CW" to "CCW", change the connection as per dotted line.

 

 

② ONE DIRECTION(일방향운전) + VARIABLE SPEED(가변) + BRAKE(제동)6W~25W

 

- To reverse the rotation from "CW" to "CCW", change the connection as per dotted line.

- When switch from "RUN" to "STOP", electric lectric brake acts for approx. 0.5sec and motor stops instantaneously.

 

 

③ ONE DIRECTION(일방향운전) + VARIABLE SPEED(가변) + BRAKE(제동)40W~120W

 

- To reverse the rotation from "CW" to "CCW", change the connection as per dotted line.

- When switch from "RUN" to "STOP", electric brake acts for approx. 0.5sec and motor stops instantaneously.

 

 

④ REVERSIBLE(정역운전) + VARIABLE SPEED(가변)6W~120W

 

- Operate SW2 after motor stops completely.

 

 

⑤ REVERSIBLE(정역운전) + VARIABLE SPEED(가변) + BRAKE(제동)6W~25W

 

- When switch from "RUN" to "STOP", electric brake acts for approx. 0.5sec and motor stops instantaneously.

- During this period, do not operate switch SW4, SW5.

- Switching of SW4, SW5 should be earlier than switching of SW2, SW3 from STOP to RUN.

 

 

⑥ REVERSIBLE(정역운전) + VARIABLE SPEED(가변) + BRAKE(제동)40W~120W

 

- When switch from "RUN" to "STOP", electric brake acts for approx. 0.5sec and motor stops instantaneously.

- During this period, do not operate switch SW4, SW5.

- Switching of SW4 SW5 should be earlier than switching Switching of SW4, SW5 should be earlier than switching of SW2, SW3 from STOP to RUN.

 

 

■ EXTERNAL SPEED SETTING (외부 속도 설정)

REMOTOE SPEED CONTROL(원격 조작)

- Set the built-in speed setting knob to "0".

- Recommend twisted shield wire and grounding this shield to socket terminal No.2.

 

 

MULTI-STEP SPEED SETTING (다단계 속도 설정)

- Set the built-in speed setting knob to "0".

- Set external resistor VR1, VR2, VR3 to multi-setp speed and switch with SW8.

 

 

⑦ REVERSIBLE(정역운전) + VARIABLE SPEED(가변) + BRAKE(제동)CONTROLLER의 전기 BRAKE는 사용하지 않을때6W~120W

- Electric brake of control unit is NOT USED simultaneously.

- Operate SW2 after motor stops completely.

- Closing of switch SW1 should be 0.5sec earlier than starting signal of SW4 and SW6.

- Switching for START Switching for START STOP - should be done by switch should be done by switch SW4 and SW6 leaving switch SW1 as "ON".

 

 

⑧ REVERSIBLE(정역운전) + VARIABLE SPEED(가변) + BRAKE(제동)CONTROLLER의 전기 BRAKE는 사용할 때6W~25W

 

 

40W~120W

 

- Electric brake of control unit is USED simultaneously.

- When switch from "RUN" to "STOP", electric brake acts and motor stops instantaneously.

- perate SW4 SW5 after motor stops completely Operate SW4, SW5 after motor stops completely.

- Switching of switch SW4 and SW5 should be earlier than switching of switch SW2, SW3, SW9 from "STOP" to "RUN".

- Closing of switch SW1 should be 0.5sec earlier than starting signal of SW2, SW3 and SW9.

- Switching for START-STOP should be done by switch SW2, SW3 and SW9 leaving switch SW1 as "ON".

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.