Digital power control manufacturer
- Three single phase controllers in one unit to save space and expense.
- Operated by one temperature controller(output is same) or three temperature controllers(separate operation). And also used as one three phase regulator(Only on three-phase four-wire system)
- With high accuracy, stability and reliability.

Feature
Three in One
- One unit including three single phase regulators saves space.
- Suitable for multiple power regulators or SSR’s.
- Different control method or different rated current can be mixed up.
- Capable to be used three single phase regulators or one three phase regulator(Three phase four wire system)
- Operated by three temperature controllers or just one temperature controller.
Saving expense and space
- More economical and more spacious than three single phase regulators.
Accuracy, Stability and Reliability
- Accuracy is enhanced by compensation algorithm comparing to different regulators.
- Long experience and know-how for digital technology since its first domestic digital power regulator allows it to be placed on the top of stability and reliability.
Ordering Code

| ① NO. of phase | S : Single phase | 
| ② Control method | Note 1) P : Phase-Angle Z : Zero-Crossing | 
| ③ Model | M : Multi-Type | 
| ④ Rated voltage | 1 : 110V / 2 : 220V / 3 : 380V / 4 : 440V | 
| ⑤ Rated current | 25A ~ 160A | 
| ⑥ Option | Note 2) Additional 60℃ temperature sensor installation | 
| ⑦ Cooling | 25A, 40A : Cooling fan option / More than 55A Cooling fan basically installed | 
Note 1) Control method is fixed when ordering.
Note 2) 60℃ temperature sensor is installed as an option, there is no alarming but just bimetal switch is on when temperature of heatsink reaches 60℃.
Specification
| Model | MULTI | 
|---|---|
| Rated Voltage | 110V / 220V / 380V / 440V, 50/60Hz | 
| Allowance of voltage | ±10% of rated voltage | 
| Rated current | 25A ~ 160A | 
| Frequency | 50/60Hz (Auto selectable) | 
| Minimum load | 1A | 
| Output range | Zero-Crossing 0~100% / Phase-Angle 0~97% | 
| PCB power | Less than 70A : 12~24VDC / More than 90A : 220VAC | 
| Withstand voltage | 2.3KVAC (1 Min.) | 
| Insulation resistance | 220MΩ | 
| Input signal | 4~20mA 3CH (1~5VDC Select on ordering) | 
| Output relay | N.O. 3CH / N.C. 3CH (IC ≤ 1A) | 
| Control method | Select one between phase-angle and zero-crossing | 
| Cooling | Less than 40A : Natural cooling / More than 55A : Cooling fan basically installed | 
| Alarm | Over Current, Over Temperature of heatsink(60℃, 80℃), Fuse failure, Load Failure, SCR failure | 
| Ambient Temp. | 0 ~ 40℃ | 
| Humidity | 40% ~ 85% RH (No condensation) | 
| Display | Six three color LED’s |