ORAND
Description
Feature
Phase Controlled Feeder Controller
- Rating Input : AC220~440V 50~60Hz Free Voltage
- Output: 0~100% (0 ~ 180`) conductin interval phase control
- Max. Allowable Current : 25A
- Memory Function : 2-Channel (M1 / M2)
- External Selection Control: 2-Channel (2ch control)
- Dimension : 62(W) x 200(D) x 145(H)
Item | OVC-250 | Remark | ||
Rating Input | AC220V ~ 440V 50~60Hz Free Voltage | |||
Output | Setting method |
Encoder, External VR. 4~20mA/0~20mA/1~5V/0~5V/0~10V |
||
Setting range | 0 ~ 100% (0~180˚) Conduction interval phase control | |||
Setting angular resolution | 0.1% | |||
Allowable current | Max 25A | |||
Control Type | Digital phase control by CPU | |||
Control | Run stop Control | External input ON/OFF control |
On/Off Control (such as PLC) by external input Dry/Wet contact (12V, 24V) Input polarity change setup : (+)electrode/(-)electrode |
|
Panel adjustment | Run, Stop Key | |||
Vibration amplitude control | Analog input | Output control by 4~20mA/0~20mA/1~5V/0~5V/0~10V Analog signal | ||
External VR control | External Vr connection output control | |||
2CH selsection control | Select and operate M1/M2 by external input | |||
Output Signal | Sync (contact point signal) | |||
Soft Start | 0.1~5.0 Sec setup (Unit : 0.1s) | |||
Soft Stop | 0.1~5.0 Sec setup (Unit : 0.1s) | |||
Memory Function |
2-Channel(M1/M2 key) Output rate. parameter WRITE/READ |
|||
Data Memory Method | EEPROM | |||
Display | OP Panel |
7-Seg : indicates Output Rate. Vibration Level, Parameter, and Error Code Dot LED : indicates Run, Remote, Feed-back, and Lock |
||
Remote Display Device | Maximum distance : 1.2Km (Option) | |||
Protection Function | When overheated. It stops operation and displays Error Code. | |||
Cooling Method | Natural Air-Cooling | |||
Conditions For USE | Surrounding Temp. | 0 ~ 40℃ | ||
Surrounding Humid. | 10 ~ 90% | |||
Spec | Weight | 1.25Kg | ||
Dimension | 62(W) x 200(D) x 145(H) |