Search

M&C ENGINEERING

M&C ENGINEERING

M&C ENGINEERING

M&C ENGINEERING

HomeManufacturersM&C ENGINEERING
1/1
M&C ENGINEERING

M&C ENGINEERING

[Signal Processor] 열식질량유량계 - Thermal

Model

Series

-


Transaction Process

Please contact the manufacturer/supplier.

Payment

Contact the manufacturer/supplier.

Delivery

Contact the manufacturer/supplier.

Shipment

Contact the manufacturer/supplier.

Origin

Contact the manufacturer/supplier.


Description

Thermal Signal Processor Model 926

Housing Available:

JIC NEMA 4 (STANDARD), JIC NEMA 4, 7, 9 Explosion proof Others Housings available upon request.

Standard Feature:

std. linearization of all transducer calibration curves to .05% FS 12-bit linearization-output step size 0.02% FS switching power supply for all internal voltages for minimum heat generation and maximum efficiency

test socket for all critical voltages 4-20 MADC isolated output all input & output are EMI conditioned all lines are protected from external RF radiation from communication radios as well as providing full protection against transmission of internal signals

 

 

Feature

Flow Rate Display

Vacuum Fluorescent or LED numbers and engineering units legends


Flow Totalizer

8 digit readout

30 days backup battery for count

Totalizer with pulse output

normally +12 VDC @ 30 milliseconds standard, options are +5, +24 VDC etc.

as well as NPN transistor open collector

 

 

Options

Batch counter

Alarm Outputs

Hi/Lo set points

Dual Range/Dual Fluids

Dual range is taking one flowrange and dividing it into two separate flowranges

for the 4-20 MADC output, switch selectable

Dual fluids is one transducer calibrated for two fluids, switch selectable


Temperature Range

-40°C to 70°C without display

-20°C to 70°C with flow rate or totalizer display

 

 

Power

110v AC; 220v AC @ 1/2 Amp; 24v DC @ 1 Amp


Isolated Output

Current 4 to 20 milliamps

1000 ohm (maximum load 

voltage 0 to 10 MV

0 to 100 MV

0 to 5 VDC

1 to 5 VDC

high impedence load

power is supplied by internal 30 volt source  

Download

Manual-M&C Engineering-Thermal mass Flowmeter - Thermal-926

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.