LS ELECTRIC

LS ELECTRIC

Servo Drive

Model

Series

Servo/Motion (Smart Automation Solution)


Transaction Process

Please contact Komachine.

Payment

Please contact Komachine.

Delivery

Please contact Komachine.

Shipment

Please contact Komachine.

Origin

Please contact Komachine.


Description

L7S

Pulse, Analog Command Type

 

Features

ㆍEasy to USE

   - Easy Gain Tuning with Automatic Inertia Estimating Function

   - Easy Setting Built-in Panel Operator

   - Many I/O Contacts and Various Functions (Digital Input: 10 contacts, Digital Output:8 contacts / Analog input, output : 2 contacts) ]

ㆍReliability for Protection Function

   - CE, RoHS Certificated

   - Drive Protection Function and Warn Function

ㆍHigh Response for Precision Control

   - High Resolutions Serial type Encoder (19Bit, BiSS)

   - Improved Speed Response (≒1Khz) Frequency

 

Specification

L7SA

Item \ Type Name L7SA001ㅁ L7SA002ㅁ L7SA004ㅁ L7SA008ㅁ L7SA010ㅁ L7SA020ㅁ L7SA035ㅁ L7SA050ㅁ L7SA075Bㅁ L7SA150Bㅁ
Input Power Main Power Supply 3 Phase AC200 ~ 230[V](-15 ~ +10[%]), 50 ~ 60[Hz]
Control Power Supply Single Phase AC200 ~ 230[V](-15 ~ +10[%]), 50 ~ 60[Hz]
Rated Current[A] 1.4 1.7 3.0 5.2 6.75 13.5 16.7 32 39.4 76
Peak Current[A] 4.2 5.1 9.0 15.6 20.25 40.5 50.1 96 98.5 190
Encoder Type Quad. Type Incremental Line Driver 2,000~10,000[P/R] Serial Type 18Bit(100WC M8 only), 19bit, 20bit(DD motor only)
Control Performance Speed Control Speed Control Range Maximum 1: 5000
Frequency Response Maximum 1 [kHz] or above (When using 19bit Serial Encoder
Speed Command DC -10 [V]~+10 [V] (Reverse rotation in case of negative voltage)
Accel/Decel Time Straight or S-curve acceleration/deceleration (0-10,000 [ms], possible to be set by one [ms] unit)
Speed Variation Ratio ±0.01 [%] or lower [when load changes between 0 and 100%] ±0.1[%] or lower [temperature 25 ±10°C]
Position Control Input Frequency 1[Mpps], Line Driver / 200[kpps], Open Collector
Input Pulse Type Symbol + Pulse Series, CW+CCW, A/B Phase
Electric Gear Ratio Four digital gear ratios can be set, selected and tuned.
Torque Control Torque Command DC-10~+10 [V] (Reverse direction torque in case of negative voltage)
Speed Limit DC 0~10 [V], internal speed command within ±1[%]
Repetition accuracy Within ±1[%]
Input/Output Signal Analog Input Input Range DC -10 ~ 10[V]
Resolution 12[bit]
Analog Output Output Range DC -10 ~ 10[V]
Resolution 12[bit]
Digital Input Total 10 Input Channels(assignment available)
SVON, SPD1, SPD2, SPD3, ALMRST, DIR, CCWLIM, CWLIM, EMG, STOP, EGEAR1, EGEAR2, PCON, GAIN2, P_CLR, T_LMT, MODE, ABS_RQ, ZCLAMP
Above 19 functions can be used selectively for assignment Signal can be set as positive logic or negative logic
Digital Output Total 5 Channels(assignment available), 3 Channels(set as alarm code)
ALARM, READY, ZSPD, BRAKE, INPOS, TLMT, VLMT, INSPD, WARN
Above 9 outputs can be used selectively for assignment Signal can be set as positive logic or negative logic
Communication RS-422 Accessible to PC software and the RS422 server
USB Status monitoring, JOG operation, parameter upload/download are available with PC Software
Encoder Serial BiSS encoder and quadrature encoder supported
Encoder Output Type Random pre-scale output through FPGA (maximum 6.4 Mpps)
Built-in functions Dynamic Braking Standard built-in (activated when the servo alarm goes off or when the servo is off)
Regenerative Braking Both default built-in and external installation possible
Display Seven segments (5 DIGIT)
Setting Function Loader (SET, MODE, UP, and [DOWN] keys)
Additional Function Auto gain tuning, phase Z detection, manual JOG operation, program JOG operation, automatic analog input calibration
Protective Function Overcurrent, overload, overvoltage, insufficient voltage, main power input problem, control power input problem, overspeed, motor cable, overheat(power module overheat, abnormal drive operation’s temp), encoder problem, over-regenerative, sensor problem, communication problem
Operation Environment Operating Temperature / Storage Temperature 0 ~ 50[°C] / -20 ~ 70[°C]
Operating Humidity / Storage Humidity Below 80[%]RH / Below 90[%]RH(avoid dew-condensation)
Environment Indoor, Avoid corrosive, inflammable gas or liquid, and electrically conductive dust.

* L7SA075, L7SA150 models are not applicable to incremental type.

 

L7SB

Download

Catalog-LS ELECTRIC-Servo Drive-Xmotion Catalog

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.