Search

LS ELECTRIC

LS ELECTRIC

LS ELECTRIC

LS ELECTRIC

HomeManufacturersLS ELECTRIC
1/1
LS ELECTRIC

LS ELECTRIC

PLC MASTER-K Series

Model

Series

PLC (Smart Automation Solution)


Transaction Process

Please contact Komachine.

Payment

Please contact Komachine.

Delivery

Please contact Komachine.

Shipment

Please contact Komachine.

Origin

Please contact Komachine.


Description

K120S

Powerful & compact block-type PLC CPU, digital I/O and power part are embedded in block-type PLCs, which is very compact and easy to install in area you want for system configuration. Through various built-in function, the user can configure a cost-effective system.

 

Features

K80S Features

Compact and high-function block type

ㆍBase: 10, 20, 30, 40, 60 points
ㆍExpansion: 10, 20 points

 

Various built-in functions for applications

ㆍHSC 1 point, Pulse output 1 point

ㆍPID (Max. 8 loops), Pulse catch 8 points

ㆍBuilt-in RS-232C I/F 1Ch: 4 (Rx), 7 (Tx), 5 (SG)

 

Various applications with special/comm. modules

ㆍAnalog input/output: G7F-ADHA

ㆍAnalog input: G7F-AD2A

ㆍAnalog timer: G7F-AT2A

ㆍCnet I/F: RS-232C, RS-422

ㆍFnet (Master)/Rnet (Master)

ㆍProfibus-DP (Slave)/DeviceNet (Slave)

ㆍRTC/Memory pack

On-line edit in KGL WIN

 

K120S Features

High-performance and various block type

ㆍEconomic type: 10/14/20/30 points (10/14 points: 2points built-in Analog Timer)

ㆍStandard type: 20/30/40/60 points

ㆍVarious expansion modules: input, output, mixed modules

ㆍP area extended for SMART I/O application (P000~P63F)

ㆍHigh-speed processing speed: 0.1㎲/step (standard type)

ㆍBattery-less backup
  - Program backup: EEPROM backup while online editing
  - Data backup: Super capacitor

ㆍVarious input handing: Input filter, pulse catch

 

Enhanced communication functions

ㆍBuilt-in RS-232C (Ch0) and RS-485 (Ch1) support *1)

ㆍTransmitting data monitoring support: KGLWIN

ㆍVarious option modules
  - Cnet (RS-232C, RS-422) Fnet/Rnet (master module)
  - Profibus-DP/DeviceNet (slave module)

 

Powerful built-in functions

ㆍHigh-speed counter: 32-bit signed operation
  - Counter range: -2,147,483,648 ~ 2,147,483,647
  - Function: ring counter, latch counter, comparison (equal/zone/task), RPM

ㆍPositioning function (DRT/DT type)
  - Control axis: 2 axes (100kHz)
  - Operation method: single, repeat
  - Operation mode: end, keep, continuous
  - Additional functions: return to origin, JOG operation, PWM output

ㆍPID operation function
  - Relay/PRC auto-tuning, SV ramp, delta MV, PWM output, position/velocity algorithm

 

Various expansion modules

ㆍ7 Digital I/O modules: G7E-DR(08/10/20)A, G7E-TR10A, G7E-DC08A, G7E-RY(08/16)A

ㆍ9 Analog I/O modules: G7F-ADHA(B/C), G7F-AD2A(B), G7F-DA2I(V), G7F-AT2A, G7F-RD2A

ㆍ6 Comm. modules: G7L-CUEB(C), G7L-DBEA, G7L-PBEA, G7L-FUEA, G7L-RUEA

ㆍ2 Option modules: G7E-RTCA, G7M-M256B

 

Specification

K80S System Specifications

Item Specifications
Operation method Cyclic execution of stored program, Time-driven operation, Interrupt task execution
Program language Mnemonic, Ladder
I/O control method Scan synchronized batch processing method (Refresh method), Direct method by program
Number of instructions Basic 30
Application 218
Processing speed 0.5㎲/Step
Program memory capacity 7Ksteps
Memory device P (I/O Relay) P0000~P31F (512 points)
M (Auxiliary relay) M0000~M191F (3,072 points)
K (Keep relay) K0000~K031F (512 points)
L (Link relay) L0000~L063F (1,024 points)
F (Special relay) F000~F063F (1,024 points)
T (Timer) 100ms T000~T191 (192 points)
10ms T192~T255(64 points)
C (Counter) C000~C255 (256 points)
S (Step controller) S00.00~S99.99 (100 x 100)
D (Data register) D0000~D4999 (5,000 words)
Timer type ON Delay, OFF Delay, Integration, Monostable, Retriggerable timer
Counter type Up, Down, Up-Down, Ring counter
Self-diagnosis functions Watchdog timer, Memory error, I/O error, Batter error, Power supply error
Built-in special function PID control Controlled by instruction, Auto tuning, Forward/Reverse action, Forced output, Operation scan time setup
Cnet I/F function (RS-232C) Dedicated protocol, MODBUS protocol, User-defined protocol
High speed counter Counting speed 1 Phase: 16kHz (1 channel)
2 Phase: 8kHz (1 channel)
3 Counting modes
Counting method 1Phase, up/down count with program Input
1Phase, up/down count B-phase Input
2 Phase, up/down with phase difference
Multiplication 1, 2 or 4
Pulse catch Pulse width : 0.2 ms, 8points
Pulse output 2kHz
External interrupt 8 points (0.4ms)
Input filter 0~15ms (Setting by 1ms)

*1) K7M-DR10S (/DC), K7M-DT10S: Built-in RS-232C and RS-485 port. Simultaneous use is not allowed and a communication module is not available to use. Built-in Cnet dip switch: ON (RS-232C), OFF (RS-485)

 

Download

Catalog-LS ELECTRIC-PLC MASTER-K Series (Factory Automation Brochure)

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.