Description

Feature

◾Low noise and low vibration
◾If desired, the liquid ring vacuum pumps are supplied also with other motors or with motors in explosion-proof design.
◾Various chemical idusstries 
◾Vacuum drying of goods of food and medicien 
◾As shown in the figure, a runner is eccentrically assembled into the center of the casing.


 
 KVC Water Ring Pump


 
Construction type

KVC Water Ring Pump  1

Sealing water supplied from the suction port changes into the ringed shape of almost the same thickness on the inner wall of the cylinder by revolution of the runner. 
 The volume of the space surrouned by the ringed inner wall and the blade of the rummer increases and sucks in proportion to revolution and decreases and is compressed, with exhausting action through the exhaust port.  
 
 

 

KVC Water Ring Pump  2

 

LEM SeriesunitLEM25LEM50LEM90LEM125LEM150LEM250LEM325LEM425

Speed 50Hz
60Hz

rpm2800
3500
1450
1750
1450
1450

Max. compression overpressure

bar0.30.3/0.50.3(0.5")

Max. admissible pressure difference

bar1.11.1/1.51.1(1.5")

Moment of inertial of the
rotating pump parts and of the
water filling

kg/㎡0.0030.00950.0350.0530.0690.0970.140.21

Sound pressure level at a
suction pressure of 80 mbar

dB(a)6869657072

Max. gas temperature dry

200200200

satutated

100100100

Service liquid max.admissible temperature

   

materials : 0A, 0B, 0R, 4B

 808080

0F, 7C, 7R

 40--

max. viscosity

㎟/s444

max. density

kg/㎥1.21.21.2

volume of liquid up to shaft level

Liter0.30.42.42.83.24.04.34.7

max. flow resistance
of the heat exchanger

bar0.20.20.2

LPH Series

unit

LPH-45008

LPH-45311

LPH-45316

speed

rpm

1150

1450

1740

1150

1450

1740

1150

1450

1740

power of the electric motor provided for drive

kW

2.2

3/4

4

3

4

5.5

4

5.5

7.5

inertia moment of the rotating pump parts and water filling

kg x ㎡

0.05

0.063

0.09

contents of liquid in the pump upto shaft level

liter

4

5.5

7

heat to be eliminated when compres
_sing air from 120 to 1013 mbar

kW

1.3

2.1

3.1

1.6

2.5

3.5

2.1

3.2

4.6

lowest suction pressure permissible
for continuous operation at a
service water temperature of 15℃

mbar

33

33

33

max. pressure difference permissible between
suction and compression pressure

bar

1.5

1.5

1.5

1.2

1.2

1.2

1.0

min. pulley diameter permissible
in case of V-belt drive

mm

160

160

160

sound pressure level of measuring area
at a suction pressure of 80mbar

dB(A)

64

65

66

64

65

66

64

65

66

max. temperature permissible
service liquid 100℃
gas 120℃

max. viscosity permissible of service liquid 90 ㎟/s
max. flow resistance of heat exchanger 0.2bar

LPH Series

unit

LPH-55312

LPH-55316

LPH-55320

speed

rpm

1150

1450

1740

1150

1450

1740

1150

1450

1740

power of the electric motor provided for drive

kW

7.5

7.5/11

15

7.5

11

15

11

11/15

15

inertia moment of the rotating
pump parts and water filling

kg x ㎡

0.137

0.162

0.205

contents of liquid in the pump upto shaft level

liter

9

10

12

heat to be eliminated when
compressing air from 120 to_1013 mbar

kW

4.3

5.9

9

4.8

6.7

10

7.9

8.1

11.3

lowest suction pressure permis_sible
for continuous operation
at a service water temperature of 15℃

mbar

33

33

33

max. pressure difference
permissible between suction
and compression pressure

bar

1.5
(1.2)

1.5
(1.1)

1.5
(1.0)

1.5
(1.2)

1.5
(1.1)

1.3
(1.0)

1.2
(1.2)

1.1
(1.0)

10

min. pulley diameter permis
_sible in case of V-belt drive

mm

200

200

not admissible

sound pressure level of
measuring area at a suction pressure
of 80mbar

dB(A)

66

66

66

max. temperature permissible
service liquid 100℃
gas 120℃

max. viscosity permissible of service liquid 90 ㎟/s
max. flow resistance of heat exchanger 0.2bar

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.