Search

GMEDI

GMEDI

GMEDI

GMEDI

HomeManufacturersGMEDI
1/1
GMEDI

GMEDI

Needleless connectors

Model

Series

Products


Transaction Process

Please contact the manufacturer/supplier.

Payment

Contact the manufacturer/supplier.

Delivery

Contact the manufacturer/supplier.

Shipment

Contact the manufacturer/supplier.

Origin

Contact the manufacturer/supplier.


Description

GMEDI Needleless connectors

Reduce needlesticks

Our CLO Autovalve & Solo Needleless Connector helps protect you against the estimated 600,000 to 1 million needlestick injuries that occur yearly.

About

Easy disinfection

The flat, smooth surface lets you easily swab and disinfect the access point.

Reduced risk of hemolysis

The straight-through, non-tortuous fluid path reduces the risk of hemolysis.

Reduced risk of needlestick injury

The needle-free design reduces needlestick injuries.

Compliance with simplicity

A passive system, the valve supports compliance while eliminating the need for caps and cannulas

Features/Benefits

Radiology compatibility

With low-pressure power injectors up to 325 psi and a maximum flow rate of 10 mL/sec, the valve can be used in radiology.

Support for various drugs

The valve features high chemical compatibility and lipid resistance, enabling it to accommodate a wide variety of drugs.

MRI compatibility

Metal-free manufacturing enables the valve to be used in MRI.

Large age range

DEHP-free manufacturing supports neonates, pediatrics and adults.

Latex-free design

The latex-free design eliminates the potential of sensitivity to the material.

Award-winning reputation

The valve has won awards from NSPE, the North Carolina Governor and the Medical Design Excellence Awards.


GMEDI Needleless connectors  1

Promote catheter patency and effective disinfection

Our CLO 3-Way Stopcocks & Extensions Tube technology features a visible fluid path and high-flow, straight-fluid channels to enhance flushing. The fluid-filled design eliminates air space inside the connector that can trap bacteria, which cannot be flushed or disinfected.

About

Neutral clamping sequence

Requiring no clamping, anti-reflux action helps prevent blood from entering the catheter upon disconnection.

Blood reflux prevention

The connector helps maintain line patency without positive pressure flushing and clamping.

Proven three-second disinfection

A solid, sealed surface helps prevent contamination from entering the line.



GMEDI Needleless connectors  2

Connect with patients, safely

Hospitals using the CLO Manifold Needleless Connector had lower unadjusted CLABSI rated, as well as lower standardized infection Ratios, compared to hospitals not using the CLO Manifold Needleless Connector.

About

Proven three-second disinfection

A solid, sealed surface enhances workflow while helping prevent bacteria from entering the line.

Nowhere for bacteria to hide

The fluid-filled design eliminates air space inside the connector so bacteria cannot be trapped.

Clear fluid path

The visible fluid path and high-flow, straight-fluid channels enhance flushing.

Safety through simplicity

The connector fluid path is one component vs. multiple moving parts that can hide contaminants and prevent complete flushing.

Features/Benefits

Reduced occlusion risk

A bolus of fluid clears the catheter tip at disconnection, reducing risk of occlusions from reflux.

Saline flushing

The device lets you use a saline flush and lock rather than heparin that can cause risks.

Device standardization

The device supports standardizing connectors on both central and peripheral lines.



GMEDI Needleless connectors  3

Close yourself off to dangerous exposure

Our CLO Multi–Way Tube Needleless Connector partners with our CLO Autovalve & Solo Needleless Connector products to form a closed system that keeps hazardous drugs from leaking or dripping. This design helps you to safely handle the drugs.

 

About

No-drip-tip technology

The technology lets you transfer drugs without leaks while helping reduce surface contamination.

Workflow efficiency

The luer reduces the risk of exposure without adding cumbersome steps to the clinical process.

Lock-and-go design

The luer quickly and easily connects to the SmartSite needle-free valve.

Automatic safety lock

The luer lock helps prevent accidental discharges from the syringe.

 

Features/Benefits

Patented micro-aspiration technology

The technology reduces risk of exposure to hazardous drugs while the luer is disconnected from the SmartSite valve.

Manufacturing safety

The luer uses latex-, DEHP- and ABS plastic-free material.

High performance

The total volume is ~0.12 mL, flow rate is 5,948 mL/hr and internal diameter is equivalent to an 18 G device.

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.