Search

CU MEDICAL SYSTEMS

CU MEDICAL SYSTEMS

CU MEDICAL SYSTEMS

CU MEDICAL SYSTEMS

HomeManufacturersCU MEDICAL SYSTEMS
1/4
CU MEDICAL SYSTEMS

CU MEDICAL SYSTEMS

Defibrillator

Model

Series

Emergency


Transaction Process

Please contact the manufacturer/supplier.

Payment

Contact the manufacturer/supplier.

Delivery

Contact the manufacturer/supplier.

Shipment

Contact the manufacturer/supplier.

Origin

Contact the manufacturer/supplier.


Description

<tab title="Functions & Features">

▶Ambient noise detection [Auto volume adjusting]

▶Easy-to-use & manage Electrode (Displaying Life expectancy of Electrode)

▶Graphic LCD status Indicator (Device, Pads & Battery) 

▶Selectable Voice guide for both Lay Rescuer and Healthcare provider

▶ECG monitoring or multi printing via Bluetooth communication


<tab title="Specifications">

Product Exterior

Dimensions: 260 x 256 x 70 mm (Width x Length x Height)

LCD: 5inch wide, 480x272 16bit

Weight 2.4㎏ (Including the battery pack and pads)

Defibrillator

Operation Type: Dual Mode (semi-automated, manual) External Defibrillator

Output Type: e-cube biphasic (Truncated exponential type) output Energy 

AED Mode

• 150J±4J, 200J±6J at 50Ω load for adults

• 50J±2J at 50Ω load for children

Manual Mode (Optional)

• 2J±1J, 3J±1J, 5J±1J, 7J±1J, 10J±1J, 20J±2J, 30J±2J, 50J±2J, 70J±2J, 100J±4J, 150J±4J, 200J±6J at 50Ω load

Self Test 

Auto Power Self-Test / Real-time Self-Test

Daily / Weekly / Monthly Self-Test

Manual Battery Pack Self-Test (performed when the user inserts the battery pack)

ECG Analysis System

Analyzes whether the rhythms of the patient's impedance and ECG require a defibrillation

Measured Impedance Range 25Ω ~ 175Ω 

Battery

Battery Type: 12V DC, 111.1V DC, 1.9Ah Li-ion, rechargeable

Capacity: For fully charged new batteries, at least 60 shocks or 3

hours of operation at 25°C (77°F)

Standby Life (After Inserting the Battery)

If stored and managed in accordance with instructions in the document: At least 2 years from the date of installation into the i-PAD CU-SP2

Temperature Ranges for Storage and Use   

Operating Environment:

Temperature: 0°C ~ 43°C (32°F ~ 109°F)

Storage Environment:

Temperature: -20°C ~ 60°C (-4°F ~ 140°F)

Electrode

Electrode Area: 110 cm2

Cable Length: Total 120cm (Internal: 95cm, External: 25cm)

Electrode Area: 50 cm2 

Cable Length: Total 120cm (Internal: 80cm, External: 40cm)

Data Storage and Transfer

Data Storage: Saves 3 events on the internal memory (up to 17 hours per event)

SD Card:  Stores the ECG and event data from the device's internal memory through the PC software (CU-Expert).

Bluetooth: Uses Bluetooth to communicate with the Printer or the CUEM1

(ECG transmission device)


<tab title="Accessories">

Standard Package

 Device(1), Adult pads(1), Rechargeable battery (1), Battery charge Dock(1), CU-EM1(1), Printer(1), 

 Printer paper(10), SD Card(1), CU-Expert (1), Carrying case(1), User’s manual(1)

Optional Accessories

 Pediatric pads(1), Disposable battery(1), IrDA Adapter(1)

Inquiry

Komachine Inc.
Head Office:
Ace Dongbaek Tower 1-1101, 16-4,
Dongbaekjungang-ro 16beon-gil, Giheung-gu,
Yongin City, Gyeonggido, South Korea 17015
Branch Office:
606, Seoul Stratup Center, 10,
Noryangjin-ro, Dongjak-gu, Seoul, South Korea 06938
CEOCharlie Park
Corporate #535-86-00664

ⓒ2024 Komachine Inc. All rights reserved.